Terrace Roof

TR-series,TF-series

TR-series,TF-series

For this model you can select from either a strongly-curved or a flat roof design.
We have a wide variety of size variations available, so you can use this model for your outdoor living needs or as a parking space for your car.

Color

aluminium
SLC UC BKC KC BR WH

Roof Color

polycarbonate
BR AO SI
heat protection polycarbonate
polycarbonate polycarbonate
SI CL

Dimensions

Width: 1,845mm / 2,027mm / 2,754mm / 3,027mm / 3,663mm / 4,027mm / 4,572mm / 5,027mm / 5,481mm
Depth: 870mm / 1,170mm / 1,470mm / 1,770mm / 2,070mm / 2,370mm / 2,670mm / 2,970mm / 3,270mm / 3,570mm
Height: 2,400mm / 3,400mm
page top

TR-series

enlarge image

Standard Type

Standard Type

Strength

Wind pressure & Snow load resistancee

WIND 36m/sSNOW 600N/m2

Our basic, standard model.
The front frame is supported by posts, resulting in more usable undercover space.

enlarge image

Movable Post Type

Movable Post Type

Strength

Wind pressure & Snow load resistance

WIND 36m/sSNOW 600N/m2

In this structure, the girder on top of the posts supports the roof. The depth of the posts can be moved up to a maximum of 500 mm.

page top
enlarge image

Movable Post Type
(2nd Floor Installation)

Movable Post Type (2nd Floor Installation)

Strength

Wind pressure & Snow load resistance

WIND 36m/sSNOW 600N/m2

In this structure, the girder on top of the posts supports the roof.
The roof of can be attached to the balcony of an existing home.
The posts are fixed in place using the fixing brackets that attach to the wall of the balcony.

enlarge image

Wide Type
(Standard Post Type / Movable Post Type)

Wide Type (Standard Post Type / Movable Post Type)

Strength

Wind pressure & Snow load resistance

WIND 36m/sSNOW 600N/m2

The width of the roof can be moved up to a maximum of 3570 mm.
The wide space could be used as a garage.

page top

TF-series

enlarge image

Standard Type

Standard Type

Strength

Wind pressure & Snow load resistance

WIND 36m/sSNOW 600N/m2

Our basic, standard model.
The front frame is supported by posts, resulting in more usable undercover space.

enlarge image

Movable Post Type

Movable Post Type

Strength

Wind pressure & Snow load resistance

WIND 36m/sSNOW 600N/m2

In this structure, the girder on top of the posts supports the roof. The depth of the posts can be moved up to a maximum of 500 mm.

page top
enlarge image

Movable Post Type
(2nd Floor Installation)

Movable Post Type (2nd Floor Installation)

Strength

Wind pressure & Snow load resistance

WIND 36m/sSNOW 600N/m2

In this structure, the girder on top of the posts supports the roof.
The roof of can be attached to the balcony of an existing home.
The posts are fixed in place using the fixing brackets that attach to the wall of the balcony.

page top